BilletCasting runner degassing unit, the amount of hydrogen, which is 0.25-0.30 cc / 100 g, is reduced to 0.15-0.20 cc / 100 g after receiving the gas.
3-5% Cl gas mixture is offered as an option to clean alkaline impurities such as Na, K, Li.
Capacity: 35 ton/hour
Process gas: Ar, N2 (Optional Cl)
Gas injection: with 1 graphite rotor
The degassing unit consists of the following parts :
• 650 kg Liquid Aluminum capacity Crucible
• 1 Graphite Rotor (mounted on the cover)
• Pnomatic Rotor lifting system
• Gas mixing board (N2 / Ar + Optional Cl)
Ladle entrance and exit runners
• Control Board, ABB